|
|
package common
|
|
|
|
|
|
import "github.com/mizuki1412/go-core-kit/class/exception"
|
|
|
|
|
|
//物料描述
|
|
|
|
|
|
func getMatType(matName string) string {
|
|
|
switch matName {
|
|
|
case "光缆_GYTA-4B1.3":
|
|
|
return "C"
|
|
|
case "光缆_GYTA-4B1.3(m)":
|
|
|
return "C~"
|
|
|
case "光缆_GYTA-6B1.3":
|
|
|
return "D"
|
|
|
case "光缆_GYTA-6B1.3(m)":
|
|
|
return "D~"
|
|
|
case "光缆_GYTA-12B1.3", "光缆_GYTS - 12B1.3":
|
|
|
return "E"
|
|
|
case "光缆_GYTA-12B1.3(m)":
|
|
|
return "E~"
|
|
|
case "光缆_GYTA-24B1.3", "光缆_GYTA53-24B1.3":
|
|
|
return "G"
|
|
|
case "光缆_GYTA-24B1.3(m)":
|
|
|
return "G~"
|
|
|
case "光缆_GYTA-48B1.3":
|
|
|
return "I"
|
|
|
case "光缆_GYTA-48B1.3(m)":
|
|
|
return "I~"
|
|
|
case "光缆_单根钢丝加强件、低烟无卤阻燃聚烯烃护套、通信用室内蝶形引入光缆_GJXH 1B6a2(米)":
|
|
|
return "L"
|
|
|
case "光分路器_盒式封装(报价包括SC连接器插头,以1.5m长的G.657A2(B6a2)、d2.0mm尾纤为基础) 1×2":
|
|
|
return "M"
|
|
|
case "光分路器_插片式封装(报价包括光纤适配器,以1.5m长的G.657A2(B6a2)、d2.0mm尾纤,SC/UPC类型适配器及插头为基础) 1×4", "光分路器_盒式封装(报价包括SC连接器插头,以1.5m长的G.657A2(B6a2)、d2.0mm尾纤为基础) 1×4", "光分路器_插片式封装 1×4":
|
|
|
return "N"
|
|
|
case "光分路器_盒式封装(报价包括SC连接器插头,以1.5m长的G.657A2(B6a2)、d2.0mm尾纤为基础) 1×8", "光分路器_托盘式封装(报价包括光纤适配器,以1.5m长的G.657A2(B6a2)、d2.0mm尾纤,SC/UPC类型适配器及插头为基础) 1×8", "光分路器_PLC 盒式 1×8 FC/UPC d2.0 1.5m", "光分路器_PLC 盒式 1×8 SC/UPC d2.0 1.5m", "光分路器_插片式封装(报价包括光纤适配器,以1.5m长的G.657A2(B6a2)、d2.0mm尾纤,SC/UPC类型适配器及插头为基础) 1×8":
|
|
|
return "O"
|
|
|
case "光分路器_盒式封装(报价包括SC连接器插头,以1.5m长的G.657A2(B6a2)、d2.0mm尾纤为基础) 1×16", "光分路器_托盘式封装(报价包括光纤适配器,以1.5m长的G.657A2(B6a2)、d2.0mm尾纤,SC/UPC类型适配器及插头为基础) 1×16", "光分路器_盒式封装 1×16", "光分路器_托盘式封装 1×16":
|
|
|
return "P"
|
|
|
case "光分路器_盒式封装(报价包括SC连接器插头,以1.5m长的G.657A2(B6a2)、d2.0mm尾纤为基础) 1×32", "光分路器_托盘式封装(报价包括光纤适配器,以1.5m长的G.657A2(B6a2)、d2.0mm尾纤,SC/UPC类型适配器及插头为基础) 1×32", "光分路器_PLC 盒式 1×32 FC/UPC d2.0 1.5m":
|
|
|
return "Q"
|
|
|
case "光分路器_盒式封装(报价包括SC连接器插头,以1.5m长的G.657A2(B6a2)、d2.0mm尾纤为基础) 1×64", "光分路器_托盘式封装(报价包括光纤适配器,以1.5m长的G.657A2(B6a2)、d2.0mm尾纤,SC/UPC类型适配器及插头为基础) 1×64", "光分路器_盒式封装 1×64", "光分路器_托盘式封装 1×64":
|
|
|
return "R"
|
|
|
case "光缆交接箱满配箱型005:传统型-落地式-复合材料(SMC)箱体-144芯_1030×570×310(含底座)", "144芯传统光缆交接箱(SMC)_SC或FC型_含底座、14块12芯熔配一体化托盘组件(束状纤)、12个直熔单元":
|
|
|
return "T"
|
|
|
case "光缆交接箱满配箱型006:传统型-落地式-复合材料(SMC)箱体-288芯_1550×760×370(含底座)", "288芯传统光缆交接箱(SMC)_SC或FC型_含底座、28块12芯熔配一体化托盘组件(束状纤)、12个直熔单元":
|
|
|
return "U"
|
|
|
case "光缆交接箱满配箱型008:传统型-落地式-复合材料(SMC)箱体-576芯(双面)_1550×760×630(含底座)", "576芯双面传统光缆交接箱(SMC)_SC或FC型_含底座、56块12芯熔配一体化托盘组件(束状纤)、24个直熔单元":
|
|
|
return "V"
|
|
|
case "SMC非金属光缆分纤箱-16路壁挂/抱杆_385x295x110mm-2个1:8插片式安装位-满配", "SMC非金属光缆分纤箱-12芯壁挂/抱杆_ 345x235x100mm-1个1:8盒式安装位-满配", "室外型壁挂式光纤分线箱(镀锌板)_12芯":
|
|
|
return "W"
|
|
|
case "室外型壁挂式光纤分线箱(镀锌板)_24芯":
|
|
|
return "X"
|
|
|
case "光缆接头盒_双端 12芯 4孔 架空", "光缆接头盒_双端 12芯 4孔 管道":
|
|
|
return "AE"
|
|
|
case "光缆接头盒_双端 24芯 4孔 管道", "光缆接头盒_双端 24芯 4孔 架空":
|
|
|
return "AF"
|
|
|
case "光缆接头盒_双端 48芯 4孔 架空":
|
|
|
return "AG"
|
|
|
case "光跳纤_SC/PC接头":
|
|
|
return "AU"
|
|
|
case "基准光跳纤(1米,外护套3mm,不含接头)_G.652型":
|
|
|
return "AV"
|
|
|
case "光跳纤_FC/PC接头":
|
|
|
return "AW"
|
|
|
case "光跳纤_FC-FC 2M(G.652型 外护套2mm)", "光跳纤_FC-FC 2M(G.652型 外护套3mm)", "光跳纤_FC-FC 2M(G.652型 外护套3mm)_光跳纤_FC-FC 2M(G.652型 外护套3mm)":
|
|
|
return "AH"
|
|
|
case "光跳纤_FC-SC 2M(G.652型 外护套2mm)", "光跳纤_FC-SC 2M(G.652型 外护套3mm)_光跳纤_FC-SC 2M(G.652型 外护套3mm)":
|
|
|
return "AI"
|
|
|
case "光跳纤_FC-FC 3M(G.652型 外护套2mm)", "光跳纤_FC-FC 3M(G.652型 外护套3mm)":
|
|
|
return "AK"
|
|
|
case "光跳纤_FC-SC 3M(G.652型 外护套2mm)", "光跳纤_FC-SC 3M(G.652型 外护套3mm)":
|
|
|
return "AL"
|
|
|
case "光跳纤_FC-SC 15M(G.652型 外护套3mm)":
|
|
|
return "AR"
|
|
|
case "光跳纤_SC-SC 1M(G.652型 外护套3mm)":
|
|
|
return "AT"
|
|
|
case "光跳纤_SC-SC 2M(G.652型 外护套2mm)", "光跳纤_SC-SC 2M(G.652型 外护套3mm)", "光跳纤_SC-SC 2M(G.652型 外护套3mm)_光跳纤_SC-SC 2M(G.652型 外护套3mm)":
|
|
|
return "AJ"
|
|
|
case "光跳纤_SC-SC 3M(G.652型 外护套3mm)", "光跳纤_SC-SC 3M(G.652型 外护套3mm)_光跳纤_SC-SC 3M(G.652型 外护套3mm)":
|
|
|
return "AM"
|
|
|
case "光纤配线架_12芯束状尾纤_FC/PC_1.0m(0.9mm)_公开市场":
|
|
|
return "AX"
|
|
|
case "光纤配线架_熔配一体化托盘12芯_公开市场", "综合配线架_熔配一体化托盘 12芯_公开市场":
|
|
|
return "AY"
|
|
|
case "熔配一体化子框_48芯":
|
|
|
return "AZ"
|
|
|
case "光纤配线架_2000×840×300mm(线路侧)配置-满配576芯_FC型,含8个72芯机框,48块12芯熔配一体化托盘组件(束状纤)", "光纤配线架_2200x600x300mm(线路侧)配置-满配504芯_FC型,含42块12芯熔配一体化托盘组件(束状纤)、3个存储单元":
|
|
|
return "BA"
|
|
|
case "华为-扩容-MDU-GPON MDU-LAN设备B+光模块_OSG020201(含华为接入FTTx及铜线软件V2.00)", "华为-扩容-MDU-XG PON MDU-LAN设备N1光模块_OSX10GG201(含华为接入FTTx及铜线软件V2.00)", "扩容-MDU-10G EPON MDU-LAN设备PR30光模块_OSX10GE202(含华为接入FTTx及铜线软件V2.00)", "扩容-MDU-XG PON MDU-LAN设备N1光模块_OSX10GG201(含华为接入FTTx及铜线软件V2.00)":
|
|
|
return "BB"
|
|
|
case "华为-扩容-MDU-XG PON MDU-LAN盒式设备(24端口GE)_MA5821-24*GE口(含华为接入FTTx及铜线软件V2.00)", "扩容-MDU-XG PON MDU-LAN盒式设备(24端口GE)_MA5821-24*GE口(含华为接入FTTx及铜线软件V2.00)":
|
|
|
return "BC"
|
|
|
case "华为-扩容-MDU-XG PON MDU-LAN盒式设备(24端口GE+24端口POTS)_MA5822-24*GE口+24*POTS口(含华为接入FTTx及铜线软件V2.00)", "扩容-MDU-XG PON MDU-LAN盒式设备(24端口GE+24端口POTS)_MA5822-24*GE口+24*POTS口(含华为接入FTTx及铜线软件V2.00)":
|
|
|
return "BD"
|
|
|
case "扩容-MDU-10G PON MDU-LAN插卡设备POTS业务接口板(64路POTS)_MA5616-ASPB(含华为接入FTTx及铜线软件V2.00)", "扩容-MDU-10G PON MDU-LAN插卡设备系统软件_MA5616-H83SSYS01600(含华为接入FTTx及铜线软件V2.00)", "扩容-MDU-10G PON MDU-LAN插卡设备主机_MA5616(含华为接入FTTx及铜线软件V2.00)", "扩容-MDU-10G PON MDU-LAN插卡设备主控板(含单PON口,适用于XG PON)_MA5616-H833XP1A02(含华为接入FTTx及铜线软件V2.00)":
|
|
|
return "BE"
|
|
|
case "华为-扩容-安装材料费_安装材料费(1%)", "安装材料费(以成交价为基准进行计算,仅在新建场景使用)_安装材料费(1%)":
|
|
|
return "BF"
|
|
|
case "华为-扩容-督导调测费_督导费(3%)", "督导调测费(以成交价为基准进行计算)_督导费(3%)":
|
|
|
return "BG"
|
|
|
case "光纤收发器_EB200-SD1", "光纤收发器_EB200-SD1C", "光纤收发器_EB200-SS1":
|
|
|
return "BH"
|
|
|
case "金属光缆终端盒-12芯壁挂282*135*50mm_可装适配器12芯-满配", "光缆终端盒_12芯(含法兰盘/适配器型、金属)":
|
|
|
return "BI"
|
|
|
case "数字通信电缆_超5类4对UTP电缆 HSYV5E 4*2*0.5":
|
|
|
return "BJ"
|
|
|
default:
|
|
|
panic(exception.New(matName + " 无该类型材料,请添加!!!"))
|
|
|
return ""
|
|
|
}
|
|
|
}
|